Sign In | Join Free | My spintoband.com
spintoband.com
Dongguan Golden Refrigeration Equipment Co.,Ltd
Dongguan Golden Refrigeration Equipment Co.,Ltd
Home > Air Cooled Water Chiller >

High Cooling Capacity Air To Water Chiller Industrial Water Cooled Chiller

Dongguan Golden Refrigeration Equipment Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

High Cooling Capacity Air To Water Chiller Industrial Water Cooled Chiller

Brand Name : GOLDEN
Model Number : HLWH-100SHM~320SHM
Certification : CE
Place of Origin : Guangdong
MOQ : 1pcs
Price : Negotiable
Payment Terms : T/T, Western Union, L/C, MoneyGram
Supply Ability : 500pcs per month
Delivery Time : 10 working days after received your payment
Packaging Details : Wooden Case
Cooling capacity(KW) : 101-316
Chilled water flow(m³/h) : 17.4-54.3
Power supply : 380v-50hz-3ph
Heating capacity(KW) : 111-337
Condenser : Ripple Aluminum Fins Around Copper Pipe
Certificate : CE
Contact Now

Eco-friendly R407C Refrigerant Air Cooled Water Chiller


Description


Environment-friendly refrigerant air cooled water chiller with heat recovery for daily life , air source heat pump for HVAC

system.


Model HLWH~

100SM

150SM

195SM

230SM

270SM

290SM

320SM


Rated Cooling Capacity

Cooling

Capacity (KW)

101

147

196

232

268

293

316

Comp.

Input Power (KW)

34.6

48.2

63.8

70.5

82.4

90.2

98.9


Rated Heating Capacity

Heating

Capacity (KW)

111

159

212

245

284

311

337

Comp.

Input Power (KW)

34.1

47.4

62.8

69.2

80.8

88.4

97.2

Refrigerant

R407C

Power Supply

3φ-380V/50HZ

Safety Protection

Phase reversion protection,

Phase lack protection,

Overload current protection,
Discharge air temp. protection,

Low & High pressure protection,

Low temp. protection,

Water flow protection.

Number of Refrigeration Circuit

1

Capacity Control (%)

0, 50, 75, 100

Refrigerant Charge (Kg)

30

42

56

68

78

84

93

Air Cooled Heat Exchanger

Ripple Aluminum Fins Around Copper Pipe


Water Cooled Heat Exchanger

Dia.of Pipe (inch)

2-1/2"

3"

3"

3"

4"

4"

4"

Water Side

Max Pressure (MPa)

1

Chilled

Water Flow(m3/h)

17.4

25.3

33.7

39.9

46.1

50.4

54.3

Water

Pressure Drop (kPa)

28

33

48

55

61

64

66

Flow of Hot

Water(m3/h)

19.1

27.3

36.5

42.1

48.8

53.5

58.0


Axial Fan

Air Flow×1000m3/h

56.8

80.4

113.6

115.2

115.2

160.8

160.8

Power×Qty (KW)

1.2×4

2.0×4

1.2×8

1.2×8

1.2×8

2.0×8

2.0×8

Running Noise dB(A)

75

75

75

75

75

75

75

Total Weight (Kg)

1550

1960

2940

3120

3300

3480

3660

Running Weight(Kg)

1660

2140

3160

3340

3550

3730

3980


Heat Recovery


Refrigerant Charge (Kg)

35

47

54

76

85

92

101

Heat Reclaimed Volume (KW)

30

44

59

70

80

88

95

Heat Recovery

Dia.of Pipe (inch)

1-1/2"

1-1/2"

1-1/2"

2"

2"

2"

2"

Water Side Max Pressure (MPa)

1


Reclaimed Water Flow (m3/h)

5.2

7.6

10.1

12.0

13.8

15.1

16.3

Water Pressure drop (kPa)

24

23

27

27

26

26

26

Total Weight (Kg)

1720

2160

3180

3360

3550

3770

3980

Running Weight(Kg)

1870

2400

3450

3680

3910

4200

4390


Note :


1. Rated Cooling Capacity Based on : DB Temperature 35 ℃ / WB Temperature 24 ℃

Chilled water inlet/outlet temp. 12 ℃ / 7℃ , Fouling factor: 0.088㎡.°C/KW.

2. Rated Cooling Capacity Based on : DB Temperature 7℃/WB Temperature 6 ℃

Hot water inlet/outlet temp. 40 ℃ / 45 ℃ ; Hot water range: 45 ℃~45 ℃;

2. Chilled Water Range: 5~20℃ ; Lowest Ambient Temperature: -5 ℃~43 ℃;

3. Heat recovery unit water in/out temperature: 50 ℃ / 55 ℃;

4. Changes of Specification for lmprovement May Be made without Notice.


Feature:


1. Cooling capacity: 101KW - 316KW , Heating capacity : 111KW - 337KW


2 . Compact design, reliable operation;


3 . Micro-computer control intelligently, English display, and friendly interface. Operating information is clear at a glance.


4 . Micro-computer and electrical control elements are brand products and imported from world. The products has

good quality, and reliable features


5 . The unit may install on roof of the building, ground or other location, where does not need equipment room.


6 . The installation of air cooling chiller is simply in comparison with that of water cooling chiller, no need

to work with cooling tower or cooling water pipeline. The unit is compact in structure and covers small land

area .You only need to connect the water pipeline between load and evaporator and supply during installation


Unit within heat recovery , can provide hot water for daily life .


Product Show


Product Tags:

Air Cooling Units

      

Air Cooled Chilled Water System

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

High Cooling Capacity Air To Water Chiller Industrial Water Cooled Chiller Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Dongguan Golden Refrigeration Equipment Co.,Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0